Generator Excitation Systems: Static, Brushless and AVR

18.11.26 02:32 PM

In short: a synchronous generator needs DC current in its rotor field, and the excitation system supplies and controls it. Static systems feed the field through slip rings from thyristor rectifiers, while brushless systems use a shaft-mounted exciter and rotating diodes. The automatic voltage regulator (AVR) adjusts the field to hold voltage and share reactive power, with limiters that protect the machine. BTGC supports Fuji Electric steam turbine generators.

Rotor of a large synchronous machine

Power, cogeneration and desalination plants in the Kingdom must meet grid code rules for voltage control and fault ride-through.

Static or brushless

FeatureStatic excitationBrushless excitation
Field supplyThyristor rectifier through slip rings and brushesRotating exciter and diode wheel on the shaft
ResponseVery fastFast, slightly slower
MaintenanceBrushes, slip rings, power electronicsRotating diodes, fuses, exciter
Typical useLarge utility generatorsIndustrial and medium generators

What the AVR does

  • Holds terminal voltage or power factor at the set point.

  • Shares reactive power with other generators and the grid.

  • Limits over-excitation, under-excitation and volts per hertz to protect the machine.

  • Can include a power system stabiliser to damp grid oscillations, where the grid code requires it.

Power and desalination plant

Maintenance and upgrades

  • Inspect brushes and slip rings on static systems; see brushless exciters and carbon dust.

  • Check rotating diodes and fuses on brushless systems during outages.

  • Test AVR settings and limiters after changes, and keep records for grid compliance.

  • Replace obsolete analogue AVRs with digital units during major overhauls.

  • Plan with generator inspections; see generator inspection.

Fuji Electric from BTGC

Fuji Electric's power generation business supplies steam turbines and generators for conventional, combined cycle and combined heat and power plants. BTGC is the Fuji Electric partner in Saudi Arabia for power generation equipment: enquiries, spare parts and after-sales service coordination. See also synchronous generators for cogeneration and the power and utilities sector page.

Questions buyers ask

What happens if excitation is lost? The generator loses synchronism and must be tripped by protection.

Can an old AVR be upgraded? Often yes, to a digital regulator matched to the existing exciter.

Does BTGC supply Fuji Electric excitation parts? BTGC coordinates spare parts and service with Fuji Electric.

Contact the BTGC power division

Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. Request a quote.