In short: refineries, petrochemical plants, fertiliser and desalination sites need both steam and power. Cogeneration with steam turbines uses high-pressure steam to generate electricity and then supplies lower-pressure steam to the process, giving far higher overall efficiency than separate systems. The turbine type, back-pressure, extraction or condensing, must match how much process steam is needed and how much it varies. BTGC supports Fuji Electric steam turbines and generators for power generation.

Many industrial sites in the Kingdom have boilers or heat recovery steam generators and large steam demands. Choosing the right turbine configuration affects fuel use, flexibility and reliability for decades.
Turbine types
| Type | How it works | Best when |
|---|---|---|
| Back-pressure | Exhausts all steam at process pressure | Steam demand is steady and large |
| Extraction back-pressure | Supplies steam at two or more pressures | Process needs several steam levels |
| Extraction condensing | Extracts process steam and condenses the rest | Steam demand varies or power is the priority |
| Condensing | Exhausts to a condenser at vacuum | Power only, no process steam |
Matching to the site
Build a steam and power balance for normal, peak and turndown cases.
Check how often process steam demand changes, and how fast.
Consider grid connection, island operation and backup boilers.
Account for summer conditions: cooling for condensing turbines is harder in hot weather.
Plan for maintenance outages and how process steam will be supplied during them.

Operating and maintenance points
Keep steam purity within limits to avoid deposits on blades and valves.
Monitor vibration, bearing temperatures and stage pressures.
Test overspeed protection and stop valve closure regularly.
Plan major overhauls on the OEM interval; see overhaul planning.
Maintain lube oil quality; see turbine oil varnish.
Fuji Electric from BTGC
Fuji Electric's power generation business covers thermal and geothermal power plants with steam turbines and generators. BTGC is the Fuji Electric partner in Saudi Arabia for power generation equipment: enquiries, spare parts and after-sales service. See also generators for cogeneration, main steam isolation valves and the power and utilities sector page.
Questions buyers ask
Why is cogeneration more efficient? It uses the same fuel for power and process heat, so much less energy is wasted than in separate power and boiler plants.
Back-pressure or extraction condensing? Back-pressure suits steady steam demand; extraction condensing gives flexibility when steam demand varies.
Does BTGC supply Fuji Electric spare parts? Yes, for Fuji Electric steam turbines and generators.
Contact the BTGC power division
Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. Request a quote.