In short: a cable rating in a catalogue applies to standard conditions, often 30 degC air or 20 degC ground in IEC tables. In the Kingdom, air temperatures pass 50 degC, desert sand is dry and holds heat, cables run in crowded trays and trenches, and some routes sit in direct sun. Each of these reduces how much current a cable can carry safely. Applying derating factors, or calculating ratings to IEC 60287 for large circuits, avoids overheated insulation and early failures. BTGC supplies Bahra Electric power cables.

Industrial plants, solar farms, data centres and city networks in the Kingdom install long cable runs in harsh thermal conditions. Undersized cables often work for years, then fail in a hot summer.
Factors that reduce cable rating
| Factor | Why it matters |
|---|---|
| High ambient air temperature | Less temperature margin to the conductor limit |
| Ground temperature and dry soil | Dry sand has high thermal resistivity and holds heat |
| Grouping | Cables in trays, ducts or trenches heat each other |
| Solar radiation | Exposed cables gain extra heat from the sun |
| Burial depth and ducts | Deeper burial and ducts change heat dissipation |
Sizing good practice
Use site-specific ambient and soil data, not catalogue defaults.
Apply derating factors from IEC 60364-5-52 for low voltage circuits.
Calculate ratings to IEC 60287 for medium voltage and critical feeders; see MV cable selection.
Allow for future load growth and harmonics.
Consider busways for high current runs; see busway vs cables.

Reducing thermal problems on site
Use thermal backfill around buried cables where soil is poor.
Space cables in trays and avoid overfilled trenches.
Shade or cover cables exposed to direct sun.
Check terminations and joints with thermography.
Record loads and temperatures on critical feeders.
Bahra Electric from BTGC
Bahra Electric is a Saudi manufacturer of power, control and instrumentation cables and busways. BTGC is the Bahra Electric partner for plants and projects. See also control and instrumentation cables, the electrical power systems page and the power and utilities sector page.
Questions buyers ask
Why does dry sand reduce cable rating? Dry sand conducts heat poorly, so buried cables run hotter.
Which standard covers cable rating calculations? IEC 60287 is widely used for calculating current ratings.
Does BTGC supply Saudi-made cables? Yes, Bahra Electric power and control cables.
Contact the BTGC power division
Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. Request a quote.