In short: multistage compressors cool the gas between stages in intercoolers and after the last stage in aftercoolers. Good cooling cuts the power needed for the next stage, protects valves and seals from high temperature, and condenses water out of compressed air. Fouled tubes, leaks and blocked fins quietly raise power and temperatures, and in summer can force compressors to unload or trip. Regular cleaning, testing and timely replacement keep compressors efficient. BTGC supplies Rex intercoolers, aftercoolers and finned tube coolers.

Shell and tube heat exchanger tubesheet

Reciprocating and centrifugal compressors for air, gas lift, fuel gas and process gas in the Kingdom work hardest in summer, exactly when coolers are least effective because of high air and water temperatures.

Why cooler condition matters

  • Higher gas temperature into the next stage means more compression power.

  • High discharge temperatures shorten valve, ring and seal life on reciprocating compressors.

  • Poor aftercooling sends more water vapour to dryers and the air network.

  • Leaks between gas and water sides contaminate cooling water or let water into the compressor.

Common problems

ProblemCause
Scaling and fouling on water sideHard or untreated cooling water, low velocity
Fouling on gas sideOil carry-over, dust, process deposits
Blocked fins on air-cooled unitsDust and sand
Tube leaksCorrosion, vibration, erosion at inlets
Rising approach temperatureCombined effect of fouling and lower flow
Gas compression facility

Cleaning, testing and replacement

  • Trend gas outlet temperature and approach to cooling water temperature.

  • Clean water sides mechanically or chemically, and improve water treatment; see cooling water cycles.

  • Clean air-cooled fins before summer.

  • Pressure test for leaks at overhauls and plug or retube as needed.

  • Replace coolers with improved materials or designs when leaks repeat.

Rex from BTGC

Rex Heat Exchanger of India makes finned tube heat exchangers, radiators, intercoolers and aftercoolers for compressors, engines, transformers and motors. BTGC is the Rex partner in Saudi Arabia. See also transformer radiators and motor coolers, instrument air quality and the rotating equipment page.

Questions buyers ask

How do I know my intercooler is fouled? Gas outlet temperature rises for the same cooling water temperature, and compressor power increases.

Can coolers be replaced with a different design? Yes, if thermal duty, pressure ratings and connections are matched.

Does BTGC supply coolers to existing dimensions? Yes, Rex can build to match existing coolers.

Contact BTGC

Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. Request a quote.