In short: an encoder is only as useful as the signal it sends to the drive or controller. Incremental signals are simple and fast but lose position on power loss, SSI and BiSS send absolute position over a few wires, and fieldbus and industrial Ethernet interfaces such as PROFINET and EtherCAT add diagnostics and easy integration. The right choice depends on the controller, cable length, noise, update rate and safety needs. BTGC supplies TR Electronic encoders with a wide range of interfaces.

Cranes, rolling mills, conveyors, packaging lines and process machines in the Kingdom combine equipment from many suppliers. Interface choice affects commissioning time and reliability.
Common interface types
| Interface | Characteristics |
|---|---|
| Incremental (TTL or HTL) | Pulses for speed and relative position; needs homing after power loss |
| SSI and BiSS | Absolute position over a serial link; simple wiring |
| Analog (4 to 20 mA, 0 to 10 V) | Simple, but lower resolution and noise sensitive |
| PROFIBUS, CANopen | Fieldbus with addressing and diagnostics |
| PROFINET, EtherNet/IP, EtherCAT | Industrial Ethernet with fast cycle times and rich diagnostics |
| Safety protocols | For example PROFIsafe for safety-rated position |
Selection points
Match the interface supported by the drive or PLC.
Check cable length limits and noise in the installation.
Confirm update rate and resolution for the control loop.
Use diagnostics to detect faults before they cause stops.
Use safety-rated interfaces where position is part of a safety function; see safety encoders.

Installation tips
Use shielded cables and correct earthing of shields.
Separate encoder cables from power cables.
Protect connectors from dust and water.
Record encoder settings and addresses for replacements.
Check mechanical mounting and couplings; see absolute and incremental encoders.
TR Electronic from BTGC
TR Electronic of Germany makes rotary and linear encoders, including safety-rated encoders, and absolute positioning systems for heavy industry. BTGC is the TR Electronic partner in Saudi Arabia. See also laser distance measurement and the machinery handling page.
Questions buyers ask
Do absolute encoders need homing? No, they know their position at power-up.
Is SSI better than incremental? SSI gives absolute position; incremental is simpler and fast. The application decides.
Does BTGC supply encoders with fieldbus interfaces? Yes, TR Electronic encoders with many interface options.
Contact BTGC