Fire Hydrants and Fire Water Network Valves for Industrial Sites

18.11.26 08:59 AM

In short: an industrial fire water network is a ring of buried mains with hydrants, monitors and sprinkler supplies, split into sections by isolation valves so a break or repair never cuts water to the whole site. Hydrants must deliver the design flow and pressure, and every valve must open fully and stay open. Codes such as NFPA 24 cover installation, NFPA 25 covers inspection and testing, and local civil defence and insurer rules apply too. BTGC supplies AVK hydrants and valves for water and fire water networks.

AVK hydrant and valves

Refineries, petrochemical plants, warehouses, industrial cities and utilities in the Kingdom depend on fire water networks that may sit unused for years. Problems are usually found during tests or, worse, during a fire.

Network components

ComponentRole
Ring mainSupplies water from two directions
Sectional isolation valvesIsolate parts of the ring for repair
HydrantsConnection points for hoses and fire trucks
MonitorsFixed water cannons for process areas and tanks
Indicator posts and valve boxesShow valve position and give access to buried valves

Selection points

  • Wet barrel hydrants suit warm climates where freezing is not a concern.

  • Use valves and hydrants with approvals required by the project, such as UL or FM listings.

  • Choose resilient-seated gate valves with position indication for isolation; see water network valves.

  • Use corrosion protection suited to the soil and water.

  • Plan hydrant spacing and flows to the applicable code and insurer requirements.

Industrial site

Inspection and testing

  • Inspect hydrants and valves at the intervals in NFPA 25 and local rules.

  • Flow test hydrants and record pressures.

  • Exercise isolation valves through full travel.

  • Check that valves are locked or supervised open.

  • Fix leaks and damaged hydrants quickly; see fire pumps.

AVK from BTGC

AVK of Denmark makes valves, hydrants and fittings for water, wastewater and gas; AVK SVMC manufactures in the Kingdom. BTGC is the AVK partner in Saudi Arabia. Ask BTGC for the approvals held by each AVK model. See also air valves and the power and utilities sector page.

Questions buyers ask

Why use a ring main for fire water? It supplies water from two directions, so one break does not cut off the supply.

How often should hydrants be tested? At the intervals set by NFPA 25, local civil defence rules and the insurer.

Does BTGC supply fire water valves? Yes, AVK hydrants and isolation valves.

Contact the BTGC valve team

Email valves@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. Request a quote.