In short: vibration is the most useful single indicator of a large motor's health. Overall levels compared with ISO 20816 zones show whether a machine is acceptable; the frequency spectrum shows why it vibrates. Mechanical faults such as unbalance, misalignment and looseness appear at running speed and its harmonics, bearing faults at their own defect frequencies, and electrical faults at twice line frequency or as sidebands. BTGC supplies WEG MV and HV motors and diagnoses and repairs motor faults at its WEG approved service center in Jubail.

Saudi plants run large motors on compressors, pumps, fans and mills, and many are monitored by portable routes or online systems. The data is only useful if someone can read it. A vibration spectrum splits the overall level into its frequency components, and each common motor fault leaves a recognisable pattern.
Severity: how much is too much
ISO 20816, which replaces the earlier ISO 10816 parts, sets vibration evaluation zones for industrial machines by size and support type: zone A for newly commissioned machines, B for unrestricted long-term operation, C for limited operation until there is an opportunity to repair, and D for vibration severe enough to cause damage. Trends matter as much as zones: a steady rise inside zone B is an early warning.
Reading the spectrum
| Pattern | Likely cause |
|---|---|
| High 1x running speed, mainly radial, steady phase | Unbalance |
| High 1x and 2x, high axial vibration, phase shift across the coupling | Misalignment |
| Many harmonics of running speed, sometimes half-orders | Mechanical looseness, or a cracked foot or base |
| Non-synchronous peaks at bearing defect frequencies, with harmonics and sidebands | Rolling bearing defects |
| Sub-synchronous peak around 0.4 to 0.5x on sleeve bearings | Oil whirl or bearing instability |
| Peak at twice line frequency (120 Hz on the Saudi 60 Hz grid) that disappears the instant power is cut | Electrical: uneven air gap, stator problems, soft foot distorting the frame |
| Pole-pass sidebands around 1x and its harmonics | Rotor bar or end ring problems |

Separating mechanical and electrical causes
A simple test is to watch the vibration as the motor is switched off. Electrically caused vibration at twice line frequency disappears the moment power is removed, while mechanical vibration decays with speed. An uncoupled run separates motor problems from the driven machine, and motor current signature analysis adds detail on rotor bar faults.
Common motor-specific causes in the Kingdom
Soft foot and base problems after relocation or poor grouting.
Bearing damage from VFD currents, described in bearing currents in VFD-driven motors.
Lubrication problems in hot conditions, see greasing motor bearings.
Thermal bow and rotor unbalance after long standstill or high-temperature running.
Resonance of motor frames on flexible steel structures, common on skids and elevated platforms.
From diagnosis to repair
When the spectrum points to the motor, the next steps are inspection and, if needed, workshop repair: bearing replacement, rotor balancing, air gap correction, rotor bar repair or rewind, as covered in rewind or replace decisions.
WEG from BTGC
BTGC is the WEG partner in Saudi Arabia for medium and high voltage motors and MV drives. The BTGC service center in Jubail, a WEG approved service center, carries out vibration diagnosis, dynamic balancing, bearing and rotor repairs, rewinds and testing for motors of all makes. See also the rotating equipment page.
Questions buyers ask
What vibration level is acceptable for a large motor? It depends on machine size and support; ISO 20816 zones give the limits. Compare with the machine's own baseline as well.
Can vibration show electrical faults? Yes. Twice line frequency vibration and pole-pass sidebands point to air gap and rotor bar problems.
Can BTGC carry out vibration surveys? Yes, as part of motor diagnosis and repair support from the Jubail service center.
Contact the BTGC power division
Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. Request a quote.