Pumping Bitumen and Asphalt: Pump Types, Heating and Start-Up

18.11.26 01:06 PM

In short: bitumen is semi-solid at ambient temperature and very viscous even when hot, so it is pumped with positive displacement pumps kept at temperature by steam, thermal oil or electric heating. Most failures happen at start-up, when a pump tries to turn on cold, solidified product. Good heating, correct seals and a start-up routine keep bitumen pumps running. BTGC supplies Arai Pump rotary plunger and screw pumps for viscous service.

Refinery and oil facility in Saudi Arabia

Refineries, terminals, road construction and waterproofing plants in the Kingdom handle bitumen and heavy residues, typically pumped well above 100 °C.

Pump types used

TypeNotes
Rotary plunger pumpsHandle high viscosity with steady flow; suit transfer and metering
Screw pumpsSmooth, low-pulsation flow for transfer and loading
Gear pumpsCommon for smaller transfer duties
Centrifugal pumpsOnly for hot, thinner residues, since efficiency falls fast as viscosity rises

Heating and insulation

  • Jacketed pump casings and covers heated by steam or thermal oil, or electric trace heating.

  • Heat-traced, insulated suction and discharge lines with jacketed valves; see jacketed valves for bitumen.

  • Temperature indication on the pump and lines, so operators know the product is fluid before starting.

  • No overheating, which hardens bitumen and forms coke on hot surfaces.

Insulated process piping in a plant

Start-up and operation

  • Heat the pump and lines until the product is fluid, and check the shaft turns freely where possible.

  • Start with the discharge path open and the relief valve set; never close the discharge of a positive displacement pump.

  • Use packing or mechanical seals rated for the temperature, with a quench where needed.

  • Flush with flushing oil before long stops if heating will be off.

  • Check wear and clearances at overhauls; see screw pump maintenance.

Arai Pump from BTGC

Arai Pump Mfg. Co., Ltd. of Osaka makes rotary plunger pumps and screw pumps for viscous fluids. BTGC supplies Arai Pump in Saudi Arabia with spare rotors, liners and seals. See also PD pumps for viscous fluids and the oil and gas sector page.

Questions buyers ask

Why not use a centrifugal pump for bitumen? At high viscosity a centrifugal pump loses head and efficiency, while a PD pump keeps steady flow.

What causes most bitumen pump failures? Starting on cold product, which overloads shafts, couplings and seals.

Does BTGC supply spares for installed Arai pumps? Yes, rotors, liners and seals.

Contact BTGC

Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. Request a quote.