Radiation Safety for X-Ray and Isotope Gauges in Mills

18.11.26 09:06 AM

In short: thickness, profile and density gauges in mills and process plants use X-rays or radioactive isotopes because they measure accurately without touching the product. Properly designed and managed, they give very low doses to workers. Safety rests on licensing with the regulator, shielding, shutters and interlocks, clearly marked controlled areas, trained staff with dosimeters, regular surveys and leak tests, and safe disposal of old sources. X-ray gauges have the advantage of producing no radiation when switched off. BTGC supplies IMS Messsysteme X-ray and isotope measuring systems.

IMS strip measuring gauge

Steel and aluminium mills and some process plants in the Kingdom operate radiation gauges. Regulators expect clear procedures and records.

X-ray and isotope gauges compared

AspectX-ray gaugesIsotope gauges
Radiation when offNoneSource always emits; shutter controls the beam
Typical useThickness and profile in rolling millsSome thickness, density and level measurements
End of lifeElectrical equipmentSource must be returned or disposed of under licence
Main controlsInterlocks, shutters, warning lightsShielded housing, shutter, source security

Safety essentials

  • Hold the licences required by the national nuclear and radiological regulator.

  • Appoint and train a radiation protection officer.

  • Mark controlled areas and keep access restricted.

  • Check shutters, interlocks and warning lights regularly.

  • Use personal dosimeters for workers who need them and keep dose records.

Steel strip in a rolling mill

Maintenance and records

  • Work on gauges only under permit with the beam off or shutter closed.

  • Carry out radiation surveys and leak tests on sealed sources at the required intervals.

  • Keep source inventories and movement records.

  • Plan the return or disposal of old isotope sources early.

  • Consider replacing isotope gauges with X-ray systems during upgrades; see measurement modernisation.

IMS from BTGC

IMS Messsysteme of Germany supplies measuring systems for hot and cold rolling, processing lines and tube and pipe production. BTGC is the IMS partner in Saudi Arabia. See also X-ray and isotope thickness gauges, profile and flatness measurement and the metal sector page.

Questions buyers ask

Do X-ray gauges emit radiation when switched off? No, X-rays are produced only when the tube is powered.

Why do isotope sources need leak tests? To confirm the sealed source is intact and not spreading contamination.

Does BTGC supply X-ray gauges? Yes, IMS X-ray measuring systems for mills.

Contact BTGC