Control Valve Overhaul: What a Proper Rebuild Includes

16.11.26 11:05 AM

In short: a control valve that comes back from the workshop with new packing and a coat of paint has not been overhauled. A proper rebuild records how the valve arrived, finds out why it failed, restores the trim, seals, actuator and positioner to the maker's specification, and proves the result with seat, stroke and calibration tests. Done that way, the valve returns to service for a full run between turnarounds. BTGC overhauls Motoyama and other control valves at its Jubail service center and supplies genuine Motoyama spare trims.

Motoyama control valves supplied by BTGC

Turnarounds in Jubail, Yanbu and the Eastern Province send hundreds of control valves to workshops at once. The pressure is to turn them round quickly, and the risk is that each valve gets the same superficial treatment. The valves that then fail in the first months after start-up are usually the ones where the cause of the original problem was never found.

Step 1: as-found tests

Before anything is dismantled, the valve is stroke-tested and seat-tested as received, and the positioner's diagnostics are downloaded if it has them. As-found results tell the plant whether the valve was performing, what failed first and whether the overhaul interval is right. They also protect both the plant and the workshop if questions come up later.

Step 2: dismantling and inspection

PartWhat to look forTypical action
Plug and seatErosion, wire drawing, cavitation pitting, gallingLap if minor; replace with a genuine trim if worn beyond limits; review trim type if cavitation is the cause
Cage or guideErosion, scoring, galling, depositsClean or replace; check clearances
StemBending, scoring in the packing area, thread damageReplace if scored; scored stems destroy new packing
Body and bonnetErosion downstream of the seat, gasket faces, corrosionRepair faces; check wall thickness where erosion is visible
Packing and gasketsHardening, extrusion, leakage pathsAlways replace with the specified materials
ActuatorDiaphragm cracks, spring condition, piston seals, corrosionReplace diaphragm and seals; check spring rate and bench set

Step 3: reassembly to specification

  • Use genuine or specification-equivalent trim, packing and gaskets, and record part numbers.

  • Set packing load to the maker's figure; over-tight packing causes stick-slip, under-tight packing leaks.

  • Set the actuator bench set and spring range to the data sheet, and check travel and fail position.

  • Calibrate the positioner, run its auto-tune and record a new baseline signature, as described in smart valve positioners.

Valve test bench at the BTGC service center in Jubail

Step 4: final tests and documents

  • Shell test of the body if pressure parts were repaired.

  • Seat leakage test to the valve's original class, as explained in valve seat leakage classes.

  • Full stroke and step response test with the positioner.

  • A report with as-found and as-left results, parts replaced, the cause of failure and recommendations.

Use the overhaul to fix root causes

Repeated trim erosion often means the valve is wrongly sized or the trim is wrong for the pressure drop; repeated packing leaks often mean a scored stem or the wrong packing; repeated diaphragm failures can mean excessive air supply pressure. The overhaul report is where those patterns should be spotted, and where a resize or trim change is proposed. See control valve sizing and control valve cavitation.

Motoyama from BTGC

Motoyama Eng. Works, Ltd. builds globe control valves, cryogenic and bellows-seal designs, and safety relief valves. BTGC is the Motoyama partner in Saudi Arabia, supplying genuine spare trims and overhauling control valves of all makes at the BTGC service center in Jubail. See the flow control and valves page.

Questions buyers ask

How long does a control valve overhaul take? A standard globe valve can be turned round in days when parts are in stock; order trims for critical valves before the turnaround.

Can you overhaul valves of other makes? Yes. The Jubail service center overhauls control valves of all makes, using the maker's specifications and genuine parts where available.

Do we get as-found data? Yes. As-found and as-left tests are recorded in the overhaul report.

Contact the BTGC valve team

Email valves@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. Request a quote.