Encoders for Hazardous Areas: Explosion-Protected Feedback

18.11.26 02:21 PM

In short: encoders give speed and position feedback on motors, cranes, winches, valves and loading arms. In oil, gas and chemical plants many of these sit in hazardous areas, so the encoder must carry the right explosion protection, usually flameproof (Ex d) or intrinsically safe (Ex i), certified for the zone, gas group and temperature class. Cable entries and installation must keep that protection intact. BTGC supplies TR Electronic encoders.

TR Electronic rotary and linear encoders

Refineries, gas plants, terminals and offshore facilities in the Kingdom use encoders on drives, hoists and positioning systems in classified areas.

Protection types

TypeHow it worksNotes
Flameproof (Ex d)Housing contains any internal explosionRobust; cable entries and joints must be correct
Intrinsic safety (Ex i)Energy kept too low to ignite gasNeeds barriers or isolators in the safe area
Increased safety and enclosure typesPrevent sparks and hot surfacesUsed for some components and terminal boxes
Dust protection (Ex t)Enclosure keeps dust outFor dust zones such as powder handling

What to specify

  • Zone (0, 1, 2 or 20, 21, 22), gas group and temperature class from the area classification.

  • Certification scheme accepted by the owner, such as IECEx or ATEX, and any local approvals.

  • Interface and resolution needed by the drive or PLC; see encoder interfaces.

  • Ambient temperature range, since many sites see more than 50 °C in sun.

  • Shaft or hollow-shaft mounting and coupling to the machine.

Oil and gas facility with hazardous areas

Installation and upkeep

  • Use certified cable glands and keep flamepaths clean and undamaged.

  • Do not open flameproof housings live, and never modify certified equipment.

  • Inspect to the plant's hazardous area inspection scheme.

  • Choose absolute or incremental to suit the duty; see absolute or incremental.

  • Related equipment: explosion-proof motors and hazardous area plugs.

TR Electronic from BTGC

TR-Electronic makes rotary and linear encoders with a wide choice of interfaces and housings. BTGC supplies TR Electronic in Saudi Arabia; send the area classification and BTGC will propose the matching certified version. See also the oil and gas sector page.

Questions buyers ask

Can a standard encoder be put in a protective box? Only if the box and assembly are certified as a whole; a home-made enclosure is not acceptable.

Which is better, Ex d or Ex i? Both are safe when certified; Ex i needs barriers, Ex d needs careful cable entry.

Does BTGC supply replacements for installed encoders? Yes, send the nameplate and certification details.

Contact BTGC

Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. Request a quote.