In short: centrifugal pumps must never run below a minimum flow, or the liquid inside overheats and internal recirculation damages impellers and bearings. Boiler feed, pipeline and other high-energy pumps therefore have a recirculation line back to the suction tank. The valve in that line drops the full pump pressure, often well over 100 bar, so it faces some of the worst cavitation and erosion in the plant. Multi-stage trim and tight shutoff keep it working and stop wasted energy. BTGC supplies KOSO severe service control valves, including pump recirculation valves.

Power, desalination and oil and gas plants in the Kingdom run large high-pressure pumps that start, stop and turn down often. Leaking or eroded recirculation valves are a common hidden energy loss.
Minimum flow protection options
| Option | Notes |
|---|---|
| Continuous bypass orifice | Simple but wastes energy all the time |
| Modulating recirculation control valve | Opens only when flow falls; needs flow measurement and control |
| Automatic recirculation valve | Self-acting check and bypass in one body |
| On-off recirculation valve | Opens at low flow, closes when flow recovers |
Why recirculation valves wear
The full differential pressure is taken across one valve.
Hot water close to saturation flashes and cavitates.
Seat leakage when closed causes wire drawing and steady energy loss.
Frequent opening at low lift erodes trim.
Poorly designed downstream piping adds vibration.

Good practice
Specify multi-stage pressure-reducing trim designed for cavitating service; see cavitation and noise.
Require tight shutoff and check for seat leakage with temperature on the outlet line.
Size for the real minimum flow given by the pump maker.
Use back-pressure devices downstream where recommended.
Plan trim inspection at each major outage; see control valve overhaul.
KOSO from BTGC
Nihon KOSO makes severe service control valves, actuators and positioners for power, oil and gas and process plants. BTGC is the KOSO partner in Saudi Arabia, with valve testing and repair at the Jubail service center. See also feedwater and spray water valves, turbine bypass valves and the power and utilities sector page.
Questions buyers ask
Why does a pump need minimum flow? Below it, the liquid overheats and internal recirculation damages the pump.
How can I tell if a recirculation valve leaks? A warm outlet line when the valve should be closed is a common sign.
Can BTGC repair recirculation valves? Yes, at the Jubail service center, with KOSO trim parts.